Detail SONOCOOL 255

Ultrasonic device with cooling for use in pathology and analysis laboratories Technical data Inner tank dimensions: 280 × 150 × 150 mm ( l × w × d) Tank volume: 5 litres ( contact liquid) Adjustable bath temperature: 15 – 30 ° C ( at 20 ° C room temperature) Cooling power: 200 W Ultrasonic power: 180 W, adjustable in 4 steps Ultrasonic frequency: 35 kHz, SweepTec® Countdown operation: up to 100 h External dimensions: 360 × 605 × 385 mm ( l × w × d) Housing: aluminium: coated with fl ush pulls ( grips recessed inside the housing) Outlet: front left, concealed Current consumption: 1.6 A Mains connection: 230 V~ , 50/ 60 Hz Weight: 27.5 kg SONOCOOL 255 Code No. 3500 Consisting of: Ultrasonic device, sample holder PH 255, for 8 inset beakers, lid D 255 G, 10 inset beakers SD 01 à 100 ml, TICKOPUR TR 3 ( concentrate for producing the contact liquid) - 250 ml Vorteile ý ý ý ý ý ý compact design ý ý ý ý ý ý increased life span by welded tank: stainless steel AISI 316Ti, 2 mm thick ý ý ý ý ý ý lid made of glass for easy cleaning and sample observation ý ý ý ý ý ý level sensor for contact liquid as dry run protection ý ý ý ý ý ý lighted LCD display for remaining time – actual temperature – pause/ diagnostics – set time/ set temperature – ultrasonic power ý ý ý ý ý ý serial interface for remote control Inset beaker SD 01 100 ml, with ring ( package à 10 pieces) Code No. 3516 Accessories Sample holder PH 255 for 8 inset beakers SD 01 Code No. 3511 Decalcifi cation of bone tissue in pathology Decalcifying of bone tissue is an important step of histological preparation of samples ( e.g. in oncology) . Only decalcifi ed samples can be used artefact-free for followed diagnosis. Compared to standard methods, the processing time is extremely shortened. - no destroying of the morphologic structure of samples - quantity of aggressive decalcifying liquids is reduced - faster results of diagnosis Use in analysys laboratories With SONOCOOL® the cathalytic effect of ultrasound can also be used when sonicating temperature-sensitive samples. Exotherm reactions are possible because of the integrated cooling system, processes are faster and more effective.
Tampilkan Lebih Banyak